Model Configurator App What equipment would you like to protect?SelectElectrical Distribution Panel with various breakers: Either Mains or Sub/DistributionVariable Frequency DrivesControl Panels: PLC, Robotics, Process ControlsSelect Panel AmpsSelectLess than 250 amps250-400 amps401-800 amps801-1200 amps1201-1800 amps1801-2500 amps2501-3000 ampsMore than 3000 amps2/10 Is this panel a Service Entrance or Generator Transfer Panel? Yes No 3/10 Distribution Board / Sub-Panel? Yes No 4/10 Any Options Required? Surge Counter, Dry Relay Contacts, Audible Alarm, Remote Lights? Yes No 5/10 Control Cabinet w/PLC? Yes If not, please revisit Question 3/10 above.2/14 Is this panel a Service Entrance or Generator Transfer Panel? Yes No 2/18 Is this panel a Service Entrance or Generator Transfer Panel? Yes No 2/22 Is this panel a Service Entrance or Generator Transfer Panel? Yes No 2/26 Is this panel a Service Entrance or Generator Transfer Panel? Yes No 2/30 Is this panel a Service Entrance or Generator Transfer Panel? Yes No 2/35 Is this panel a Service Entrance or Generator Transfer Panel? Yes No Wye (3 Wires + Neutral + Ground) RM-ST603Yx (Choose Options from Data Sheet) Delta (3 Wires + Ground) RM-ST603Nx (Choose Options from Data Sheet) Installation Sheet-Delta Wye Type 1 Level Diagram Data/Install Sheets RM 3Nx 3Yx Distribution Board / Subpanel / No Options Required Wye (3 Wires + Neutral + Ground) RM-ST403Yx Delta (3 Wires + Ground) RM-ST403Nx Installation Sheet Delta Wye Type 1 Level Diagram Data/Install Sheets RM-ST50 3Nx 3YxControl Cabinets Level 1: Wye (3 Wires + Neutral + Ground) RM-ST403Yx Level 1: Delta (3 Wires + Ground) RM-ST403Nx Level 2: PLC/Power Supply 120 Volt: ST-SPT120-15 240 Volt: ST-SPT240-15 Data/Install Sheets RM-ST50 SPT 3Nx 3YxService Entrance/ Generator Transfer Panel (ATS) Single Phase 120/240 Split Phase = RM-STI201S1 120 V Hot - Neutral - Ground = RM-ST1201P1 240 V Hot - Neutral - Ground = RM-ST1201P2 Three Phase LA-ST1203Yx (Wye - 3 Wire + Neutral + Ground) RM-ST1203Nx (Delta - 3 Wire + Ground) Installation Sheets Delta Wye Type 1 Level Diagram Data/Install Sheets RM LA 3Nx 3YxDistribution Board/Sub-Panel Single Phase RM-ST401S1 (Split phase 120/240) RM-ST401Px (Hot + Neutral + Ground) 120, 240, 480 Three Phase LA-ST603Yx (Wye - 3 Hot + Neutral + Ground) RM-ST403Nx (Delta - 3 Wire + Ground) Installation Sheets Delta Wye Type 1 Level Diagram Data/Install Sheets RM-ST50 LA 3Nx 3YxService Entrance/ Generator Transfer Panel (ATS) Single Phase 120/240 Split Phase = RM-ST1801S1 120 V Hot - Neutral - Ground = RM-ST1801P1 240 V Hot - Neutral - Ground = RM-ST1801P2 Three Phase Wye (3 Wire + Neutral + Ground) = LA-ST1203Yx Delta (3 Wire + Ground) = RM-ST1803Nx Installation Sheets Delta Wye Data/Install Sheets RM LA 3Nx 3Yx Distribution Board/ Sub-Panel Single Phase 120/240 Split Phase = RM-ST1201S1 120 V Hot - Neutral - Ground = RM-ST1201P1 240 V Hot - Neutral - Ground = RM-ST1201P2 Three Phase Wye (3 Wire + Neutral + Ground) = LA-ST603Yx Delta (3 Wire + Ground) = RM-ST1203Nx Installation Sheets Delta Wye Data/Install Sheets RM LA 3Nx 3YxService Entrance/ Generator Transfer Panel (ATS) Single Phase 120/240 Split Phase = RMST1801S1 120 V Hot - Neutral - Ground = RM-ST1801P1 240 V Hot - Neutral - Ground = RM-ST1801P2 Three Phase Wye (3 Wire + Neutral + Ground) = LA-ST1203Yx Delta (3 Wire + Ground) = LA-ST1803Nx Installation Sheets Delta Wye Type 2 & 3 Level Diagram Data/Install Sheets RM LA 3Nx 3YxDistribution Board/ Sub-Panel Single Phase 120/240 Split Phase = RM-ST1801P1 120 V Hot - Neutral - Ground = RM-ST1801P1 240 V Hot - Neutral - Ground = RM-ST1801P2 Three Phase Wye (3 Wire + Neutral + Ground) = LA-ST1203Yx Delta (3 Wire + Ground) = RM-ST1803Nx Installation Sheets Delta Wye Type 2 & 3 Level Diagram Data/Install Sheets RM LA 3Nx 3YxService Entrance/Generator Transfer Panel (ATS) Three Phase Wye (3 Wire + Neutral + Ground) = LA-ST2403Yx OR = ST-LSEA3Yx Delta (3 Wire + Ground) = LA-ST2403Nx OR = ST-LSEA3Nx Installation Sheets Delta Wye Type 2 & 3 Level Diagram Data/Install Sheets LA 3Nx 3Yx ST-LSEA Distribution Board/ Sub-Panel Single Phase Wye (3 Wire + Neutral + Ground) = LA-ST1803Yx Delta (3 Wire + Ground) = LA-ST1803Nx Installation Sheets Delta Wye Type 2 /3 Level Diagram Data/Install Sheets LA 3Nx 3YxService Entrance/Generator Transfer Panel (ATS) Three Phase Wye (3 Wire + Neutral + Ground) = LA-ST3003Yx OR ST-SMLA3Yx Delta (3 Wire + Ground) = LA-ST3003Nx OR ST-SMLA3Nx Installation Sheets Delta Wye Type 2/3 Level Diagram Data/Install Sheets LA 3Nx 3Yx ST-SMLADistribution Board/Sub-Panel Three Phase Wye (3 Wire + Neutral + Ground) = LA-ST2403ZYx OR ST-LSEA3Yx Delta (3 Wire + Ground) = LA-ST2403Nx OR LSEA3Nx Installation Sheets Delta Wye Type 2/3 Level Diagram Data/Install Sheets LA 3Nx 3Yx ST-LSEAService Entrance/Generator Transfer Panel (ATS) Three Phase Wye (3 Wire + Neutral + Ground) = ST-SILA3YM Delta (3 Wire + Ground) = ST-SILA3xM Installation Sheets Delta Wye Type 2/3 Level Diagram Data/Install Sheets 3Nx 3Yx ST-SILA3YxM Distribution Board/Sub-Panel Three Phase Wye (3 Wire + Neutral + Ground) = LA-ST3003Yx OR ST-SMLA3Yx Delta (3 Wire + Ground) = LA-ST3003Nx OR ST-SMLA3Nx Installation Sheets Delta Wye Type 2/3 Level Diagram Data/Install Sheets LA 3Nx 3Yx ST-SMLAContact info@sinetamer.com or your local SineTamer DistributorSelect kw/hpSelectUp to 37 kw / 50 hpUp to 150 kw / 200 hpUp to or Over 200 kw / 400 hpVariable Frequency Drives 10-50 HP Up to 37 kw / 50 hp or multiple small VFD's up to 37 kw / 50 hp in a single cabinet = 3 phase 240 volt = RM-ST503N2 3 phase 480 volt = RM-ST503N4 3 phase 525 volt = RM-VS2103N6 3 phase 525 volt = RM-VS2103N6 Data/Install Sheets 3Nx RM-ST50 RM VS210 VS220Variable Frequency Drives 75kW/100hp - 150kW/200hp Up to 75kW/100 hp = 3 phase 240 volt = RM-ST503N2 3 phase 480 volt = RM-ST503N4 3 phase 525 volt = RM-VS2103N6 3 phase 690 volt = RM-VS2103N7 Up to 150kW/200 hp = 3 phase 240 volt = RM-ST1203N2 3 phase 480 volt = RM-ST1203N4 3 phase 525 volt = RM-VS2203N6 3 phase 690 volt = RM-VS2203N7 Data/Install Sheets 3Nx RM-ST50 RM VS210 VS220Variable Frequency Drives 300kW/400hp and Larger Up to 300kW/400 hp = 3 phase 240 volt = RM-ST1803N2 3 phase 480 volt = RM-ST1803N4 3 phase 525 volt = RM-VS2203N6 3 phase 690 volt = RM-VS2203N7 Larger than 300kW/400hp Contact Us: +1-817-483-8497 Data/Install Sheets 3Nx RM-ST50 RM VS210 VS220Control Cabinets Level 1 Wye (3 Wires + Neutral + Ground) RM-ST503yx Delta (3 Wires + Ground) RM-ST503Nx Level 2 PLC/Power Supply 120 Volt: ST-SP1P1-15 240 Volt: ST-SP1P2-15 OR 120 Volt: ST-PCMF1P1-DIN 240 Volt: ST-PCMF1P2-DIN Data/Install Sheets RM-ST50 SPT 3Nx 3Yx PMCF Install SineTamer App Install × Tap then “Add to Home Screen” ×